| OTHER INFORMATION AND FEATURES |
|
How The TriMetric Determines That Batteries
Are Charged: When the TriMetric senses that batteries are charged, it resets the "days since charged" display to 0.00 and (at user option) resets the "amp hours" to 0.00 and the "Battery % Full" to 100%. The TriMetric determines that the batteries are "charged" when the battery voltage rises above a user programmed "charged voltage" (adjustable from 10.0-35.0 volts within 0.1 volt) and the charging amps goes below a user programmable "charge current
criteria" (adjustable from 1-100 amps within 1 amp). This condition must remain for 20 seconds.
User Selectable Efficiency Factor: Amp hours may be monitored without an "efficiency factor," meaning that the "charge" and "discharge" current for the "net amp hours" reading are both accumulated at exactly 100% rate. Or a "charge efficiency" factor may be manually set from 60% to 100% in 1% increments. This means that the discharging current will subtract from amp hours at 100% rate, where as the charging current accumulates at the lower specified rate, to approximate the "charge efficiency" of the battery. This compensates for the fact that you don't get quite as much charge out of a battery as you put in. The Same Reliable, Proven Measurement Circuit: This TriMetric circuit has proven accurate and reliable for over three years in production. All programmed information retained when meter unpowered. Remote Locatable: Up to 55 feet with four #22 ga. wires. Up to 150 feet with #18 wire. Longer distances are possible with larger wire size. Bright Display With Low Current Draw: Requires about 30mA with display on-about 16mA with display off. Size: Designed to fit into a standard "double-gang" electrical box mounted 90 degrees from the usual position. See accessories section (on the back) for suitable enclosure. Panel size ( inches): 41/2 x 43/4 x 13/4 deep . |
|
MODEL 2020 HOMEPAGE
OPERATION AND SPECIFICATIONS
EXTRA DATA BATTERY MONITOR ACCESSORIES Bogart Engineering Homepage |